 TFS110D.doc
Version 1.0
15.03.2001
VI TELEFILTER
Filter Specification
TFS 110D
1/5
Measurement condition
Ambient temperature : Input power level : Terminating impedances : 23 C 0 dBm for input: for output:
890 || - 5,6 pF 680 || - 5,9 pF
Characteristics
Remark: Reference level for the relative attenuation arel of the TFS 110 D is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre (reference) frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae.
Data
Insertion loss (Reference level) Centre frequency Pass band shape Bandwidth 3 10 20 30 40 ae
typ. value 11,9 dB
tolerance / limit max. 13 dB
fc at ambient temperature TA (fCAT) (3 dB-BW) at ambient temperature: 965 1695 2255 2600 2840
arel
110,592 0,035 MHz Gaussian
dB bandwidth dB bandwidth dB bandwidth dB bandwidth dB bandwidth
kHz kHz kHz kHz kHz
min. min.
900 1600
kHz kHz kHz kHz kHz
max. 2420 max. 2700 max. 3070
Relative attenuation fc fc fc fc fc fc + -
fc ......... fc 450 kHz ... fc 1210 kHz ... fc 1395 kHz ... fc 1535 kHz ... fc 5,5 kHz ... fc + 10,0 MHz ... fc -
450 kHz 800 kHz 1395 1535 5,50 10,0 5,5 kHz kHz MHz MHz MHz fc ... fc 800 kHz fc ... fc 800 kHz
2,5 dB 8 dB 22 32 45 40...42 55...45 dB dB dB dB dB<
max. max. min. min. min. min. min.
3 10 20 30 40 38 40
dB dB dB dB dB dB dB
Group delay ( mean value ) : Group delay ripple (p-p) : Deviation from linear phase (p-p):
1,2 s 160 ns 3 20 C 0 ppm/K - 0,036 ppm/K
max. 300 ns
Frequency inversion temperature ( To ) Temperature coefficient ( Tc1f ) 1st order *) Temperature coefficient ( Tc2f ) 2nd order **) Operating temperature range Storage temperature range Input power level Permissible DC voltage Permissible AC voltage VDC Vpp
max. 7,5 ppm/K - 20 C ... + 85 C - 25 C ... + 90 C
-
max.
10 12 10
dBm V V
*) fc(Hz) = Tc1f(ppm/K) x (T - To) x fTo (MHz) ** ) fc(Hz) = Tc2f(ppm/K) x (T - To) x fTo (MHz) fTo is reference frequency fc at frequency inversion temperature (To )
Generated:
Dunzow W.
Checked/Approved:
Dr. Bert Wall
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 e-mail: tft@telefilter.com
Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 e-mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS110D.doc
Version 1.0
15.03.2001
VI TELEFILTER
3. Package :
(All dimensions in mm)
Filter Specification
TFS 110D
2/5
6,4 0,2 1
TFS 110 D tft N12
13,20 0,20
Datecode: L M N .......
Year+month 1999 2000 2001 .........
3,0 Max. 10,16 5,08 3 4
1
2
5 6 3
10
9
8 7 12,0
6
4. 50 - matching network ( Principal schemes ) :
10 9 TFS tft 8 7 6
Scheme 1.
L1
50 110 D N3 3 4 5
L4 C2 L3 50
Balanced ( scheme 1, 2) 1 - Input 5 - Output 2 - Input 4 - Output 3 - Package Ground. 7, 8, 9 - Not Connected Ground.
C1 L2
1
2
10
9 TFS tft
8
7
6
C1 50 C2
10
110 D N12 3 4 5
Scheme 2.
C4 L2 C3 50
L1
1
2
9 TFS tft
8
7
6
Scheme 3.
L1 50 L2
10 9 TFS tft 8 7 6 110 D N12 3 4 5
L4 C2 L3 50
Unbalanced ( scheme 3, 4) 1 - Input 5 - Output 2 - Input 4 - Output 3 - Package Ground. 7, 8, 9 - Not Connected Ground.
C1
1
2
C1 50 C2 L1
1
110 D N12 3 4 5
Scheme 4.
C4 L2 C3 50
2
For final test we use scheme 1. About matching element values see Application Note.
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 e-mail: tft@telefilter.com
Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 e-mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS110D.doc
Version 1.0
15.03.2001
VI TELEFILTER
5. Stability Characteristics :
Filter Specification
TFS 110D
3/5
After the following tests the filter shall meet the whole specification: 1. Shock: 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6
2. Vibration:
3. Resistance to solder heat (reflow):
max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
6. Packing :
Tape & Reel: DIN IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: Trailer
EMBOSSED CARRIER TAPE
1700 min 300 mm min 500 mm min 300 mm
Tape (all dimensions in mm) W Po Do E F G (min) P2 P1 D1(min) Ao Bo CT : : : : : : : : : : : : 24 0,3 4 0,1 1,5 + 0,1 1,75 0,1 11,5 0,1 0,6 2 0,1 12 0,1 1,5 7,1 0,2 13,9 0,2 21,5 0,1
Do Po P
2
E A
o
F D CT B
o 1
W
G
P1
COVER TAPE
W2
Reel (all dimensions in mm): A W1 W2 (max) N (min) C : : : : : 330 24,4 + 2/0 30,4 60 13 0,2
C A
W1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on the right side of the tape.
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 e-mail: tft@telefilter.com
Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 e-mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS110D.doc
Version 1.0
15.03.2001
VI TELEFILTER
7. Air reflow temperature conditions :
Filter Specification
TFS 110D
4/5
1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods main-heating periods 150 C - 170 C over 200 C 60 sec. - 90 sec. 20 sec. - 25 sec. peak temperature 255 C 5 C
Air reflow profile
260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240
Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 e-mail: tft@telefilter.com
Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 e-mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS110D.doc
Version 1.0
15.03.2001
VI TELEFILTER
Filter Specification
TFS 110D
5/5
8. History :
Version 1.0 Reason of Changes Generate filter specification according to customer requirements. Name Dunzow W. Date 15.03.2001
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 e-mail: tft@telefilter.com
Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 e-mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.


▲Up To Search▲   

 
Price & Availability of TFS110D

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X